MODEL : 1140A

브랜드 ECTRON
판매가격 전화문의 (031-713-5988)
포인트 0점
배송정보 유료(주문시 결제)
점포택배 / 평균 7일 이내 도착(토,일,공휴일 제외)

상품 재고 보유중입니다.

제품 정보

The Model 1140A provides four calibration functions: precise simulation of thermocouple signals, precise measurement of thermocouple signals, generation of accurate dc voltages from microvolt level to ±11 volts, and measurement of dc voltages over the same range. The thermocouple simulation and measurement accuracies are the highest in the industry, affording a margin of calibration accuracy heretofore unavailable.

Using a high-speed microcontroller, the 1140A offers such unique features as an autozero function to correct the zero reading of a non-ideal thermocouple. For repetitive operations, 100 sets of operating conditions can be committed to memory for future retrieval, including automatic sequencing from one condition to the next. Using one of the several interfaces, all functions can be programmed and executed under computer control.

With an output impedance of less than 0.05 Ω on all ranges, high accuracy is maintained with an absolute minimum of loading error.

ALIGNMENT AND CALIBRATION
Calibration of the 1140A is a simple procedure that can be completed with a minimum of test equipment. In fact the majority of the instrument’s alignment can be accomplished with only a short across the front-panel terminals.

Alignment is performed by the instrument’s firmware and the user is guided by front panel instructions. There are no potentiometers or other internal controls to adjust. A switch inside the unit enables the alignment function.

Alignment is carried out in several steps, allowing alignment of all functions or a subset to be performed separately. Full alignment calibration requires a known 10 V reference, a null meter with microvolt resolution, and a shorting jumper. These accessories are available from Ectron Corporation.

FEATURES

  • 0.06°C Accuracy for Common Thermocouple Types, including cold junction compensation (not including temperature extremes)
  • Simulate and Measure Thermocouples
  • Source and Measure dc Microvolts to Volts, nV Resolution
  • Dc Accuracy of 0.0025% + 2.0 µV for Six Months, for both source and measure modes
  • Output Impedance of 0.05 Ω, All Ranges
  • USB Remote Interface Included

 

· 제품 사양

Thermocouple Accuracy- Source and Measure

Includes accuracy, conformity, cold-junction compensation, noise, stability, and temperature ( ±3° of Tcal )

Does not include errors in external thermocouple wire

b07e75daf246df0af6d0a7572a37a1a4_1521607046_3926.jpg

b07e75daf246df0af6d0a7572a37a1a4_1521607267_6258.jpg
 

 

· 제품 구성

OPTIONS AND ACCESSORIES

  • IEEE-488-2, Ethernet, and RS-232 interfaces
  • Rechargeable battery
  • Rack mounting
  • 1120 emulation mode
  • Carrying case
  • Calibration test kit

 

· 제품 필수 상세정보

품명 상품페이지 참고
모델명 상품페이지 참고
법에 의한 인증·허가 등을 받았음을 확인할 수 있는 경우 그에 대한 사항 상품페이지 참고
제조국 또는 원산지 상품페이지 참고
제조자 상품페이지 참고
A/S 책임자와 전화번호 또는 소비자상담 관련 전화번호 상품페이지 참고

관련 제품

등록된 제품이 없습니다.

제품 자료

등록된 자료가 없습니다.

구매후기

등록된 구매후기

구매후기가 없습니다.

배송 및 교환

배송

배송 방법 : 택배
배송 지역 : 전국지역
배송 비용 : 3,000원 (50,000원 이상 구매 시 무료)
배송 기간 : 2일 ~ 7일
배송 안내 : - 산간벽지나 도서지방은 별도의 추가금액을 지불하셔야 하는 경우가 있습니다.
고객님께서 주문하신 상품은 입금 확인후 배송해 드립니다. 다만, 상품종류에 따라서 상품의 배송이 다소 지연될 수 있습니다.

교환/반품

교환 및 반품이 가능한 경우
- 상품을 공급 받으신 날로부터 7일이내 단, 가전제품의
  경우 포장을 개봉하였거나 포장이 훼손되어 상품가치가 상실된 경우에는 교환/반품이 불가능합니다.
- 공급받으신 상품 및 용역의 내용이 표시.광고 내용과
  다르거나 다르게 이행된 경우에는 공급받은 날로부터 3월이내, 그사실을 알게 된 날로부터 30일이내

교환 및 반품이 불가능한 경우
- 고객님의 책임 있는 사유로 상품등이 멸실 또는 훼손된 경우. 단, 상품의 내용을 확인하기 위하여
  포장 등을 훼손한 경우는 제외
- 포장을 개봉하였거나 포장이 훼손되어 상품가치가 상실된 경우
  (예 : 가전제품, 식품, 음반 등, 단 액정화면이 부착된 노트북, LCD모니터, 디지털 카메라 등의 불량화소에
  따른 반품/교환은 제조사 기준에 따릅니다.)
- 고객님의 사용 또는 일부 소비에 의하여 상품의 가치가 현저히 감소한 경우 단, 화장품등의 경우 시용제품을 
  제공한 경우에 한 합니다.
- 시간의 경과에 의하여 재판매가 곤란할 정도로 상품등의 가치가 현저히 감소한 경우
- 복제가 가능한 상품등의 포장을 훼손한 경우
  (자세한 내용은 고객만족센터 1:1 E-MAIL상담을 이용해 주시기 바랍니다.)

※ 고객님의 마음이 바뀌어 교환, 반품을 하실 경우 상품반송 비용은 고객님께서 부담하셔야 합니다.
  (색상 교환, 사이즈 교환 등 포함)