Lowest-cost calibration to -196 °C
If you need to do calibrations at the triple point of argon but don’t want the complexity and cost of using an argon triple point cell, Fluke Calibration's Model 7196B LN2 Comparison Calibrators will solve your problems. And they do it for less than half the price of other argon triple point simulators.
The nominal boiling point of nitrogen is –196°C at one atmosphere of pressure. The defining triple point of argon is –189.3442°C. While there is a difference between the nominal boiling point of nitrogen and the argon triple point, the difference can be corrected for mathematically, and an uncertainty of less than 2 mK from the actual argon triple point is achievable.
Fluke Calibration's LN2 Comparison Calibrators consist of a vacuum-sealed stainless steel Dewar Flask, a high-purity copper block, and a precision-fit lid. The dewar is filled with LN2 and the copper block is suspended in it; an SPRT is inserted into the block and a calibration is performed against your own calibrated SPRT. The 7196B-4 includes four 8-mm (0.32") wells. The 7196B-13 includes five 8-mm (0.32") wells and eight 6.35-mm (0.25") wells.
Fluke Calibration's LN2 Comparison Calibrators are neither expensive nor complicated to use. If you need supporting data or would like to discuss the theory of operation of an LN2 Comparison Calibrator, call Fluke Calibration today. (Or come to one of our calibration training courses and we’ll show you.)
Specifications | |
Temperature | Nominal –196°C depending on atmospheric pressure |
Thermal Wells | 7196B-4: four 8 mm (0.32") I.D. wells 7196B-13: five 8 mm (0.32") I.D. wells, eight 6.35 mm (0.25") I.D. wells Both blocks: 275 mm immersion from top of lid to bottom of well, 150 mm immersion into copper block |
Dimensions (outer diameter x height) | 168 mm x 406 mm (6.6 in O.D. x 16 in) |
Temperature Stability | Typically better than 2 mK/20 min[1] |
Temperature Uniformity | <0.0004 °C |
Volume | 5.47 liters (1.45 gallons) |
[1] The equilibrium temperature will change with the atmospheric pressure (dT/dp » 0.085 mK/Pa). The actual temperature stability depends on atmospheric pressure stability. |
Model Name | Description |
---|---|
7196B-4 | LN2 Comparison Calibrator, 4 holes |
7196B-13 | LN2 Comparison Calibrator, 13 holes |
품명 | 상품페이지 참고 |
---|---|
모델명 | 상품페이지 참고 |
법에 의한 인증·허가 등을 받았음을 확인할 수 있는 경우 그에 대한 사항 | 상품페이지 참고 |
제조국 또는 원산지 | 상품페이지 참고 |
제조자 | 상품페이지 참고 |
A/S 책임자와 전화번호 또는 소비자상담 관련 전화번호 | 상품페이지 참고 |
구매후기가 없습니다.
회사명 ㈜테솔 |
대표 장지훈 |
주소 경기도 용인시 기흥구 흥덕1로 13 흥덕IT밸리 P동 102-A호
사업자 등록번호 129-81-98838 |
전화 031-713-5988 |
팩스 031-713-5983 |
E-mail sales@tessol.com
통신판매업신고번호 제 2014-용인기흥-0097호 |
개인정보 보호책임자 장인석